Filter panel not connected in any way;
after tuneup
Filter panel installed inline as normal;
after tuneup
Filter panel in bypass via remote button;
after tuneup
Notes
         
160 1.0 1.3 1.2  
80 1.0 1.0 1.2  
40 1.3 1.3 3.1 Resonance in cables to filters. Can probably fix this by adding length in January.
30 1.0 1.0 1.0  
20 1.0 1.0 3.4 Resonance in cables to filters. Can probably fix this by adding length in January.
17 1.0 1.7 2.2  
15 1.0 1.0 1.7  
12 1.0 2.9 2.3 Almost certainly have bad coax jumper. Need more PL-259s and can fix in January.
10 1.0 1.8 1.0  
6 1.1 8.0 1.1 On 40 inv vee. This is the reason to bypass.

Notes:

SWR measurements above made 11 December, 2023, W0CG.

Filters themselves are good -- verified that it is the coax switches and cabling that introduce SWR.

Remember to re-click "Bypass Filters" button after changing bands.

Bypass button is secret only known to KB7Q, K8ND, W0CG, DL8OBQ.

Bypass button is for emergencies only except for working 6.